908 355 7995 or contact a pool professional.
Goldline aqualogic no cell power 2.
If i re boot it will display correctly for about a minute and then you can feel the cylenoid looking thing clicking and then it will display as mentioned above.
Turn off the main braker unplug the yellow and orange cable above the yellow fuse top right.
Please add liquid chlorine to the pool until the issue has been resolved.
No low voltage detected when the cell power was turned on.
If you get no cell power before doing anything else here s the easiest testing method.
No cell power 1 or no cell power 2 no cell power 1 no cell power 2 go to step 1a page 4.
Same with the serial numbers on your cells and control boxes after the 5a 5e 5l 3l and 3e.
Try starting the filter pump.
Please contact tech service.
My display is saying chlorinator off no cell power and check system no cell power 2.
I tried cycling the system at the breaker level on the panel thinking there might be a glitch as well as re seating the cell connector that plugs into the panel.
Goldline controls warrantied these flow switches if they failed in the field and were of the specified lot.
In diagnostic mode it shows 0v 0a in both positive and negative polarity so something is definitely wrong.
Almost all goldline controls replacement parts have a date code.
Verify that 20 24 volts ac is present between the two yellow wires.
If no voltage is measured continue to step 1b.
Turn on the main braker and your goldline.
I called goldline and they said it is probably the main board.
This must be resolved by a certified technician.
Replace main board pcb.
Plug both wire to the fuse directly.
If the voltage is ok go to step 1c.
No cell power cell power error low volts stop.
The first 2 digits are the year of manufacture the next two the month.