If the flue is within 3 m horizontally of the roof apex the flue top must be at least 600 mm above the roof apex.
Gas flue height above roof.
This reduces the actual required height by 12 inches from our previous calculation of 64 inches.
If the pipe is farther than 10 feet from the roof.
Vent caps 12 and smaller may terminate a distance above the roof if 8 feet or more away from a vertical surface as follows.
This means that below 38 degree roof pitches that the height of the flue outlet should be at least 1800mm above the roof when not close to the ridge and above 38 degree roof pitches the flue outlet height should be 2300mm horizontally back to the roof flue height figures are given in the table above where the flue is not close to the ridge.
This is for masonry chimneys.
Gas fireplace direct vent termination cap clearance distances clearances between the gas fireplace exhaust vent and other building components or features.
So 28 inches plus 24 inches is a chimney height of only 52 inches.
Single wall metal pipe shall extend at least 2 feet 610 mm above the highest point where it passes through a roof of a building and at least 2 feet 610 mm higher than any portion of a.
The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.
The 1992 vent sizing tables require that all type b gas vents terminate above the roof with a listed cap or listed roof assembly in accordance with the manufacturer s instructions.
The minimum height of the top of the flue varies depending on where it is on the roof.
If the flue is over 3 m from the roof apex the flue top must be 1 000 mm minimum above the roof and at least 3 m horizontally from.
Details about chimney height rooftop clearance requirements on buildings for all types of chimneys is at chimney height clearance code.
For a gas vent or type l vent this height must be 2 ft 0 61m or more.
Roof pitch rise run in inchesminimum height flat to 7 12 1 0 foot above the roof surface 7 12 to 8 12 1 5 feet above the roof surface 8 12 to 9 12 2 0 feet above the roof surface.
Single wall metal pipe shall terminate at least 5 feet 1524 mm in vertical height above the highest connected equipment draft hood outlet or flue collar.
Per the 10 and 2 rule once you are at the level of the peak you only need to be 2 feet above it.